HomePage Menus Use Parameter settings Gauge ToolsCablings Downloading Contact

Langue - Language - Lengua : Français - English - Español

 The cablings with TelePcCn Pro

Examples of cablings

  1. Cabling of a boitier of sharing or distributor
  2. Correspondence of connectors DB9-DB25
  3. Cabling without signal of control - CNC NUM puts into series 700
  4. Cabling with signal of control - CNC NUM puts into series 700
  5. Cabling with signal of control - CNC NUM puts into series 1000
  6. Cabling of a grip Jaeger Male 27 brooches
  7. Cabling of the bench of preregulation EPB TMA 310 P

Cabling of a boitier of division(sharing) or distributor

If we use a case of sharing put into series, the cable joining the PC to the distributor has to contain 5 threads and the signals must not be crossed.


         PC DB25 distributor PC

          TD     2---------------------/2    TD   Sending

          RD     3---------------------/3    RD   Receiving

      0V     7---------------------/7    GND

         RTS   4---------------------/4   RTS

         CTS     5---------------------/5    CTS


 

Correspondence of connectors DB9-DB25

- CABLING OF SERIAL PORTS  PC -

Correspondences DB9 / DB25


  US signal   DB9  DB25   name          Name Fr

DCD    1    9    Dated Quarryman     Detect Liaison détéctée

RD     2    3    Receive Data        Réception of the data

TD     3    2    Passed on Dated     Data transmission

DTR    4   20    Dated Air           Terminal Ready Terminal ready to receive

GND    5    7    Ground Masse        Signal or Mass

DSR    6    6    Dated Set           Ready Prêt to work

RTS    7    4    Request             To Send Demande of sending

CTS    8    5    Clear               To Send Prêt to send

LAUGHED9    22   Boxing              Ring Indicator


 

Cabling without signal of control - CNC NUM puts into series 700

Case of the CNC NUM puts into series 700

Without signal of control:


  CNC                                           PC DB25  DB9

  TD      2   -------------/--------------   3    2   RD Sending

  RD      3   -------------/--------------   2    3   TD Receiving       

  0V      7   -------------/--------------   7    5   GND

  RTS     4  No connected           |-----   4    7   RTS   Rebouclage

                            Pontage |                 des signaux

  CTS     5   -----|                |-----   5    8   CTS   de contrôle

                   |

  DCD     8   -----|  Pontage direct sur les broches

                   |

  DTR     20  -----|

It is with this type of cabling that it is  rather necessary to use TelePcCn for a NUM 7XX by using the control of stream RTS / CTS.

This type of cabling is the simplest to realize, it requires only an armoured cable 3 threads. The length of the maximum transmission link for a speed of 9600 Bauds does not have to exceed 25 metres. With good conditions of transmissions ( few parasites) we can affect approximately 40 metres.  You should not connect the mass of the cable with the frame of the machine.

Cabling with signal of control - CNC NUM puts into series 700

With signal of control:


  CNC                                    PC DB25  DB9

  TD      2   -------------/--------------   3    2   RD Receiving

  RD      3   -------------/--------------   2    3   TD Sending       

  0V      7   -------------/--------------   7    5   GND

  RTS     4   -------------/--------------   6    6   DSR

                        

  CTS     5   -------------/--------------   20   4   DTR

  DCD     8   -----|                |-----   4    7   RTS   Rebouclage

                   |                |                      des signaux

  DTR    20   -----|                |-----   5    8   CTS   de contrôle

( Direct Decking on brooches at the level of the connector)

 

Cabling with signal of control - CNC NUM puts into series 1000

 

Case of the CNC NUM puts into series 1000-1020-1040-1060


  CNC                                    PC DB25  DB9

  TD      2   -------------/--------------   3    2   RD Réception

  RD      3   -------------/--------------   2    3   TD Emission       

  0V       7    --------------/-----------------    7    5   GND

  RTS     4   -------------/--------------   5    8   CTS

  CTS     5   -------------/--------------   4    7   RTS

  DCD     8   -----|                |-----   6    6   DSR   Rebouclâge

                   |                |                       des signaux

  DTR     20   ----|                |-----   8    1   DCD   de contrôle

                   |                |

  DSR     6   -----|                |-----   20   4   DTR


( Direct Decking on brooches at the level of the connector)

Parameter setting of the connection puts into series

             CNC NUM 1060           PC

        N of Line               :0 or 1          Port COM         : COM N

        Speed in sending        :9600            Speed of trans.  :9600 or more

        Speed in receiving      :9600

        Bit of start            :1

        Bits of dated           :8               Bits of data     :7

        Bit of stop             :1               Bit of stop      :1

        Parity                  :without         Parity           :pair

        Protocol                :without

        Control of stream       : RTS / CTS

Problems of reception in the case of a CNC NUM on 1060

 

In certain cases, according to the used version of Windows and the power of the microphone computer, it is necessary to reduce the speed of reception of the programs.

PARAMETER SETTINGS - CNC NUM on 1060

****************************************

Here is the configuration to create on the CNC NUM on 1060

 

PARAMETER SETTING OF LINES SERIES

- 1 - Parameter setting Configuration 1 (Sending)

Number of line              :line 1

Standard                    :RS232

Speed of receiving          :9600 

Speed of sending            :9600

Nbr of bits of start        :1

Nbr of bits of dated        :8

Nbr of bits of stop         :1

Parity                      :without

Protocol                    :without

Control of stream           : RTS / CTS

Logical name                :Com1

Configuration 1/12          :validated

- 2 - Parameter setting Configuration 2 (Receiving)

Number of line              :line 1

Standard                    :RS232

Speed of receiving          :600 

Speed of sending            :600

Nbr of bits of start        :1

Nbr of bits of dated        :8

Nbr of bits of stop         :1

Parity                      :without

Protocol                    :without

Control of stream           : RTS / CTS

Logical name                :Com2

Configuration 2/12          :validated

During the sending of a program (PC - > CN) you have to choose the configuration 1/12 (Com1).

During the receiving of a program (CN - > PC) you have to choose the configuration 2/12 (Com2).

The selection is made with the arrows of the keyboard <-  ->.

 

Cabling of a grip Jaeger Male 27 brooches

 

Case of the NUM 760 F with embeded reader GNT 27 and taken male "Jeager" 27 brooches.


         CNC Jeager 27 Broches Mâle              PC DB25

        TD      2  - ----------/---------   3   RD Receiving

        RD      3  -----------/----------   2   TD Sending

        0V      7   ----------/----------   7   GND

        RTS     4  No connected      |---   4   RTS   Rebouclage

                                     |                des signaux

        CTS     5   ---|             |---   5   CTS   de contrôle

                       |

        DCD     8   ---|

                       |

        DTR     20  ---|


     Disconnect the reader and link the cable with the free grip DB 25 ' in the air '.

     It's better to realize a cable of connection without signal of control.

 

Cabling of the bench of preregulation EPB TMA 310 P

 

To receive the information from the bench EPB, it is necessary to realize a simplified cable.


EPB      DB 9                                  PC   DB25

RD           2      --------------/-------------      RD     3

TD           3      --------------/-------------      TD     2

GNG          5      --------------/-------------      GND    7

RTS          7      ---|                 |---         RTS    4

CTS          8      ---| Pont            |---         CTS    5